T3C Series UV-Vis Spectrophotometer
At present, the main products of Yi spectrum instrument are: handheld Raman spectrometer, portable Raman spectrometer, micro Raman spectrometer series products; visible spectrophotometer, ultraviolet visible spectrophotometer, quasi double beam ultraviolet visible spectrophotometer, double beam ultraviolet visible spectrophotometer series products;
Key words:
Classification:
Product accessories:
Hotline:
Details Introduction
- Characteristic
- Function
- Parameter
- Configuration
- Video
- Accessory
-
- Commodity name: T3C Series UV-Vis Spectrophotometer
Product Features
● High stability: Optimized optical system and integrated aluminum alloy base structure design to ensure long-term reliability and stability of the instrument.
● High degree of intelligence: dual CPU embedded system hardware design is very reliable, 128X64 bit LCD display, rich instructions, simple and convenient use, support U disk data export; Custom wavelength correction and wavelength automatic calibration functions, eliminating manual adjustment links; The service time of the light source is automatically accumulated, which is convenient for understanding and viewing. The light source switch menu can be closed when the instrument is not in use, effectively prolonging the service life of the instrument. Chinese, english dual language can be automatically switched.
● Full menu function: built-in photometric measurement, quantitative measurement, standard curve, multi-wavelength measurement and other special programs.
● Convenient data processing: it can store up to 1000 sets of experimental data, and can also be equipped with built-in and external micro printer output, or can be equipped with ego spectrum analysis software and computer connection to realize more data processing and analysis functions.
● There are many optional accessories: 8-slot automatic sample rack, single-slot micro sample rack (smaller can measure 50ul samples),5-10cm sample rack (suitable for water quality testing), single-slot or three-slot water bath cuvette rack (suitable for the requirements of constant temperature sample testing), expanding more application fields.
* Optional PC-side anti-control software will realize more application functionsProduct function
● Photometric measurement: You can select the single-point test wavelength and test method you need in the range of 190-1100nm to measure the absorbance or transmittance of the sample. The concentration of the sample can also be read directly by inputting the standard sample concentration or concentration factor.
● Quantitative measurement: measure the sample solution of unknown concentration through the curve of known parameter factor or automatically establish the standard solution curve; It has first-order, first-order zero-crossing, second-order and third-order curve fitting, absorption correction such as single wavelength correction and double wavelength, and three-point method. The standard curve can be stored and called.
● Multi-wavelength measurement: It can set up to 30 wavelength points to measure the absorbance or transmittance of the sample solution.
● Auxiliary functions: deuterium lamp, tungsten lamp lighting cumulative time, deuterium lamp, tungsten lamp independent turn off and on, ultraviolet and visible light switching wavelength point selection, operating language selection (Chinese, English), wavelength automatic calibration.Main Technical Parameters
Model
U-T3C
Optical System
C- T Monochromator Structure, 1200/mm holographic grating
wavelength drive
automatic
wavelength range
190-1100nm
spectral bandwidth
2nm
wavelength accuracy
±0.8nm
wavelength repeatability
≤ 0.4nm
transmittance accuracy
±0.3%T
transmittance than repeatability
≤ 0.1%T
stray light
≤ 0.05%T @ 220,360nm
luminosity range
0-200% T,-0.4-4A,0-99999C(0-99999F)
light source
deuterium lamp and tungsten lamp
stability
±0 .. 001A/h
noise
0.0005A/h
regression equation
has
data display
128 X64 graphic liquid crystal display
operating system language
, english dual language automatic switching
data output
USB
input voltage and frequency
90-250V/AC 50-60HZ
sample room
is large enough to be placed 10cm cuvette sample rack
other functions
wavelength automatic correction, the light source is automatically switched, and the lighting time is automatically accumulated, U disk data export
size
450mm × 390mm × 210mm
weight
12kg
product standard configuration
● host 1
● Power cord 1
● 1cm 4-slot manual cuvette rack 1
● 1cm standard glass cuvette 1 set 4
● 1cm standard Shi Ying cuvette 1 set 2
● Main machine instruction manual 1
● Dust cover 1
Product Features
● High stability: Optimized optical system and integrated aluminum alloy base structure design to ensure long-term reliability and stability of the instrument.
● High degree of intelligence: dual CPU embedded system hardware design is very reliable, 128X64 bit LCD display, rich instructions, simple and convenient use, support U disk data export; Custom wavelength correction and wavelength automatic calibration functions, eliminating manual adjustment links; The service time of the light source is automatically accumulated, which is convenient for understanding and viewing. The light source switch menu can be closed when the instrument is not in use, effectively prolonging the service life of the instrument. Chinese, english dual language can be automatically switched.
● Full menu function: built-in photometric measurement, quantitative measurement, standard curve, multi-wavelength measurement and other special programs.
● Convenient data processing: it can store up to 1000 sets of experimental data, and can also be equipped with built-in and external micro printer output, or can be equipped with ego spectrum analysis software and computer connection to realize more data processing and analysis functions.
● There are many optional accessories: 8-slot automatic sample rack, single-slot micro sample rack (smaller can measure 50ul samples),5-10cm sample rack (suitable for water quality testing), single-slot or three-slot water bath cuvette rack (suitable for the requirements of constant temperature sample testing), expanding more application fields.
* Optional PC-side anti-control software will realize more application functions
Product function
● Photometric measurement: You can select the single-point test wavelength and test method you need in the range of 190-1100nm to measure the absorbance or transmittance of the sample. The concentration of the sample can also be read directly by inputting the standard sample concentration or concentration factor.
● Quantitative measurement: measure the sample solution of unknown concentration through the curve of known parameter factor or automatically establish the standard solution curve; It has first-order, first-order zero-crossing, second-order and third-order curve fitting, absorption correction such as single wavelength correction and double wavelength, and three-point method. The standard curve can be stored and called.
● Multi-wavelength measurement: It can set up to 30 wavelength points to measure the absorbance or transmittance of the sample solution.
● Auxiliary functions: deuterium lamp, tungsten lamp lighting cumulative time, deuterium lamp, tungsten lamp independent turn off and on, ultraviolet and visible light switching wavelength point selection, operating language selection (Chinese, English), wavelength automatic calibration.
Main Technical Parameters
|
Model |
U-T3C |
|
Optical System |
C- T Monochromator Structure, 1200/mm holographic grating |
|
wavelength drive |
automatic |
|
wavelength range |
190-1100nm |
|
spectral bandwidth |
2nm |
|
wavelength accuracy |
±0.8nm |
|
wavelength repeatability |
≤ 0.4nm |
|
transmittance accuracy |
±0.3%T |
|
transmittance than repeatability |
≤ 0.1%T |
|
stray light |
≤ 0.05%T @ 220,360nm |
|
luminosity range |
0-200% T,-0.4-4A,0-99999C(0-99999F) |
|
light source |
deuterium lamp and tungsten lamp |
|
stability |
±0 .. 001A/h |
|
noise |
0.0005A/h |
|
regression equation |
has |
|
data display |
128 X64 graphic liquid crystal display |
|
operating system language |
, english dual language automatic switching |
|
data output |
USB |
|
input voltage and frequency |
90-250V/AC 50-60HZ |
|
sample room |
is large enough to be placed 10cm cuvette sample rack |
|
other functions |
wavelength automatic correction, the light source is automatically switched, and the lighting time is automatically accumulated, U disk data export |
|
size |
450mm × 390mm × 210mm |
|
weight |
12kg |
product standard configuration
● host 1
● Power cord 1
● 1cm 4-slot manual cuvette rack 1
● 1cm standard glass cuvette 1 set 4
● 1cm standard Shi Ying cuvette 1 set 2
● Main machine instruction manual 1
● Dust cover 1
Previous Page