YP‑200X Nitrification‑Denitrification Rate Tester
At present, the main products of Yi spectrum instrument are: handheld Raman spectrometer, portable Raman spectrometer, micro Raman spectrometer series products; visible spectrophotometer, ultraviolet visible spectrophotometer, quasi double beam ultraviolet visible spectrophotometer, double beam ultraviolet visible spectrophotometer series products;
Key words:
Classification:
Product accessories:
Hotline:
Details Introduction
- Characteristic
- Function
- Parameter
- Configuration
- Video
- Accessory
-
- Commodity name: YP‑200X Nitrification‑Denitrification Rate Tester
Product Features
- 10‑inch large‑size touch color LCD screen with sensitive touch response for smart and convenient operation; dynamically displays various parameters for clear data presentation.
- Automatic aeration with adjustable aeration volume; aeration can be automatically turned on or off according to dissolved‑oxygen concentration.
- High‑quality dissolved‑oxygen probe for dynamic measurement of dissolved‑oxygen concentration in the nitrification reaction zone, delivering high accuracy and fast response.
- Partitioned testing: nitrification and denitrification reactions can be performed simultaneously to improve test efficiency and save testing time.
- Automatic sampling reminder function.
- Real‑time data upload and remote device status display.
- Historical data logging and report generation (laboratory management system required).
Product Functions
The nitrification‑denitrification rate tester is special‑purpose test equipment for the water‑treatment industry. By adjusting device parameters in accordance with practical treatment requirements, it simulates nitrification and denitrification reaction environments under different operating conditions in wastewater‑treatment processes. It measures the ammonia‑nitrogen removal capacity of nitrifying bacteria and nitrate‑nitrogen removal capacity of denitrifying bacteria in activated sludge, so as to evaluate the nitrification or denitrification performance of activated sludge. It provides guidance for reducing operating costs and diagnosing abnormal effluent water quality in practical production.
Application Fields
It is widely used in sewage‑treatment plants, universities, research institutes, municipal water supply and drainage projects, environmental‑protection industries and other sectors.
Model YP‑20X Product Weight 34 kg Product Dimension (L × W × H) 680 mm × 300 mm × 755 mm Mixing‑Vessel Specification 5 L, Φ210 mm, H215 mm Rotational‑Speed Range 0‑600 r/min Aeration Range 0‑40 L/min Operating‑Environment Temperature 0‑50 ℃ Voltage AC 220 V ±5% Power 150 W Measuring Range of Dissolved‑Oxygen Sensor 0‑25 mg/L (saturation: 0‑250%) Accuracy of Dissolved‑Oxygen Sensor ±0.01‑±1% (saturation 0‑100%)±0.02‑±2% (saturation 100‑250%) -
The nitrification‑denitrification rate tester is special‑purpose test equipment for the water‑treatment industry. By adjusting device parameters in accordance with practical treatment requirements, it simulates nitrification and denitrification reaction environments under different operating conditions in wastewater‑treatment processes. It measures the ammonia‑nitrogen removal capacity of nitrifying bacteria and nitrate‑nitrogen removal capacity of denitrifying bacteria in activated sludge, so as to evaluate the nitrification or denitrification performance of activated sludge. It provides guidance for reducing operating costs and diagnosing abnormal effluent water quality in practical production.
-
Model YP‑20X Product Weight 34 kg Product Dimension (L × W × H) 680 mm × 300 mm × 755 mm Mixing‑Vessel Specification 5 L, Φ210 mm, H215 mm Rotational‑Speed Range 0‑600 r/min Aeration Range 0‑40 L/min Operating‑Environment Temperature 0‑50 ℃ Voltage AC 220 V ±5% Power 150 W Measuring Range of Dissolved‑Oxygen Sensor 0‑25 mg/L (saturation: 0‑250%) Accuracy of Dissolved‑Oxygen Sensor ±0.01‑±1% (saturation 0‑100%)±0.02‑±2% (saturation 100‑250%)
Product Features
- 10‑inch large‑size touch color LCD screen with sensitive touch response for smart and convenient operation; dynamically displays various parameters for clear data presentation.
- Automatic aeration with adjustable aeration volume; aeration can be automatically turned on or off according to dissolved‑oxygen concentration.
- High‑quality dissolved‑oxygen probe for dynamic measurement of dissolved‑oxygen concentration in the nitrification reaction zone, delivering high accuracy and fast response.
- Partitioned testing: nitrification and denitrification reactions can be performed simultaneously to improve test efficiency and save testing time.
- Automatic sampling reminder function.
- Real‑time data upload and remote device status display.
- Historical data logging and report generation (laboratory management system required).
Product Functions
The nitrification‑denitrification rate tester is special‑purpose test equipment for the water‑treatment industry. By adjusting device parameters in accordance with practical treatment requirements, it simulates nitrification and denitrification reaction environments under different operating conditions in wastewater‑treatment processes. It measures the ammonia‑nitrogen removal capacity of nitrifying bacteria and nitrate‑nitrogen removal capacity of denitrifying bacteria in activated sludge, so as to evaluate the nitrification or denitrification performance of activated sludge. It provides guidance for reducing operating costs and diagnosing abnormal effluent water quality in practical production.
Application Fields
It is widely used in sewage‑treatment plants, universities, research institutes, municipal water supply and drainage projects, environmental‑protection industries and other sectors.
| Model | YP‑20X |
|---|---|
| Product Weight | 34 kg |
| Product Dimension (L × W × H) | 680 mm × 300 mm × 755 mm |
| Mixing‑Vessel Specification | 5 L, Φ210 mm, H215 mm |
| Rotational‑Speed Range | 0‑600 r/min |
| Aeration Range | 0‑40 L/min |
| Operating‑Environment Temperature | 0‑50 ℃ |
| Voltage | AC 220 V ±5% |
| Power | 150 W |
| Measuring Range of Dissolved‑Oxygen Sensor | 0‑25 mg/L (saturation: 0‑250%) |
| Accuracy of Dissolved‑Oxygen Sensor | ±0.01‑±1% (saturation 0‑100%)±0.02‑±2% (saturation 100‑250%) |