TOC-230 series total organic carbon analyzer
At present, the main products of Yi spectrum instrument are: handheld Raman spectrometer, portable Raman spectrometer, micro Raman spectrometer series products; visible spectrophotometer, ultraviolet visible spectrophotometer, quasi double beam ultraviolet visible spectrophotometer, double beam ultraviolet visible spectrophotometer series products;
Key words:
Classification:
Product accessories:
Hotline:
Details Introduction
- Characteristic
- Function
- Parameter
- Configuration
- Video
- Accessory
-
- Commodity name: TOC-230 series total organic carbon analyzer
Product Brief Introduction
Based on years of customer accumulation and product experience of water quality analyzer products, TOC-230 series of total organic carbon analyzers have been introduced with honor. TOC-230 series has two models, TOC-230W (wet) ultraviolet persulfate oxidation-NDIR detection principle and TOC-230D (dry) high temperature catalytic oxidation-NDIR detection principle. The two models can meet different concentration samples and application scenarios.
TOC-230W the application of UV persulfate oxidation-NDIR detection principle (wet), can detect the TOC concentration in water samples from 0.001 mg/L ~ 100.0 mg/L water samples. The water sample is fully oxidized and decomposed into CO2 by ultraviolet persulfate, and CO2 enters the non-dispersive infrared detection (NDIR) after drying and impurity removal under the action of carrier gas, so as to obtain the total carbon concentration in the water sample.
TOC-230D through the high temperature catalytic oxidation-NDIR detection principle (dry), can detect the TOC concentration in water samples from 0.05mg/L ~ 50000mg/L water samples. The water sample is fully burned and decomposed into carbon dioxide and water at high temperature by a high-performance oxidation catalyst in a combustion furnace. The water vapor is cooled by a condenser to remove carbon dioxide and enters a non-dispersive infrared detector (NDIR) to obtain the total carbon in the water sample. The concentration of TC, total organic carbon TOC = TC-TIC.
Product Features
● Easy-to-use 12-inch touch screen, intuitive and visible detection curve, user-friendly interface, simple and convenient operation.
● Strict selection of components, highly reflective gold-plated air chamber, highly concentrated NDIR infrared light source and highly sensitive infrared detector.
● Various detection modes, TC, TIC, TOC, NPOC, can be carried out in the same reactor.
● Electromagnetic metering pump technology, three-pipe electronic condensation dehydration technology, combustion furnace plus overheating automatic cut-off technology, temperature, pressure, flow real-time monitoring technology.
● Optional online module to realize online monitoring, and optional automatic sampling instrument to save manpower and time.
● Convenient data storage, query and password protection.
● Long product warranty and free installation and use training, as well as affordable supplies of consumables accessories, so that you can buy at ease, use at ease, after-sales worry.
● The product conforms to EP, USP and 2020 edition of "Chinese Pharmacopoeia" standards, ISO8245 international standards, HJ501-2009 national environmental protection standards, JJG 821-2005 metrological verification procedures.Product Parameters
Model
TOC-230W
TOC-230D
Digestion Method
UV Persulfate Oxidation
High Temperature Combustion Catalytic Oxidation
detection range
0.001~100.0 mg/L
0.05~35000mg/L
detection limit
0.001mg/L
0.05mg/L
Accuracy
±5%
±5%
Repeatability
≤ 3%
≤ 3%
Measurement Mode
TC, IC, TOC, NPOC
TC, IC, TOC, NPOC
salt tolerance
100g/L
100g/L
analysis time
3~8min
3~8min
detector
NDIR (non-dispersive infrared detection)
NDIR (non-dispersive infrared detection)
operation mode
host + PC Dual Mode
Host + PC Dual Mode
Power Supply
220V AC ≤ 10% 50Hz
220V AC ≤ 10% 50Hz
Application
drinking water, surface water, rivers and lakes water, tap water, industrial sewage, domestic sewage, chemical water, pharmaceutical water, experimental research water.
Product Brief Introduction
Based on years of customer accumulation and product experience of water quality analyzer products, TOC-230 series of total organic carbon analyzers have been introduced with honor. TOC-230 series has two models, TOC-230W (wet) ultraviolet persulfate oxidation-NDIR detection principle and TOC-230D (dry) high temperature catalytic oxidation-NDIR detection principle. The two models can meet different concentration samples and application scenarios.
TOC-230W the application of UV persulfate oxidation-NDIR detection principle (wet), can detect the TOC concentration in water samples from 0.001 mg/L ~ 100.0 mg/L water samples. The water sample is fully oxidized and decomposed into CO2 by ultraviolet persulfate, and CO2 enters the non-dispersive infrared detection (NDIR) after drying and impurity removal under the action of carrier gas, so as to obtain the total carbon concentration in the water sample.
TOC-230D through the high temperature catalytic oxidation-NDIR detection principle (dry), can detect the TOC concentration in water samples from 0.05mg/L ~ 50000mg/L water samples. The water sample is fully burned and decomposed into carbon dioxide and water at high temperature by a high-performance oxidation catalyst in a combustion furnace. The water vapor is cooled by a condenser to remove carbon dioxide and enters a non-dispersive infrared detector (NDIR) to obtain the total carbon in the water sample. The concentration of TC, total organic carbon TOC = TC-TIC.
Product Features
● Easy-to-use 12-inch touch screen, intuitive and visible detection curve, user-friendly interface, simple and convenient operation.
● Strict selection of components, highly reflective gold-plated air chamber, highly concentrated NDIR infrared light source and highly sensitive infrared detector.
● Various detection modes, TC, TIC, TOC, NPOC, can be carried out in the same reactor.
● Electromagnetic metering pump technology, three-pipe electronic condensation dehydration technology, combustion furnace plus overheating automatic cut-off technology, temperature, pressure, flow real-time monitoring technology.
● Optional online module to realize online monitoring, and optional automatic sampling instrument to save manpower and time.
● Convenient data storage, query and password protection.
● Long product warranty and free installation and use training, as well as affordable supplies of consumables accessories, so that you can buy at ease, use at ease, after-sales worry.
● The product conforms to EP, USP and 2020 edition of "Chinese Pharmacopoeia" standards, ISO8245 international standards, HJ501-2009 national environmental protection standards, JJG 821-2005 metrological verification procedures.
Product Parameters
Model |
TOC-230W |
TOC-230D |
Digestion Method |
UV Persulfate Oxidation |
High Temperature Combustion Catalytic Oxidation |
detection range |
0.001~100.0 mg/L |
0.05~35000mg/L |
detection limit |
0.001mg/L |
0.05mg/L |
Accuracy |
±5% |
±5% |
Repeatability |
≤ 3% |
≤ 3% |
Measurement Mode |
TC, IC, TOC, NPOC |
TC, IC, TOC, NPOC |
salt tolerance |
100g/L |
100g/L |
analysis time |
3~8min |
3~8min |
detector |
NDIR (non-dispersive infrared detection) |
NDIR (non-dispersive infrared detection) |
operation mode |
host + PC Dual Mode |
Host + PC Dual Mode |
Power Supply |
220V AC ≤ 10% 50Hz |
220V AC ≤ 10% 50Hz |
Application
drinking water, surface water, rivers and lakes water, tap water, industrial sewage, domestic sewage, chemical water, pharmaceutical water, experimental research water.